6. Setting Parameters
60
Festo P.BE-CMMP-CO-SW-EN 0708NH
By default, the factor group is set to the following units:
Size
Description
Unit
Explanation
Length
position_units
Increments
65536 Increments per revolution
Velocity
speed_units
min
-1
Revolutions per minute
Acceleration
acceleration_units
(min
-1
)/s
RPM increase per second
6.3.2
Description of the Objects
Objects treated in this chapter
Index
Object
Name
Type
Attr.
6093
h
ARRAY
position_factor
UINT32
rw
6094
h
ARRAY
velocity_encoder_ factor
UINT32
rw
6097
h
ARRAY
acceleration_factor
UINT32
rw
607E
h
VAR
polarity
UINT8
rw
Object 6093
h
: position_factor
The object
position_factor
converts all length units of the application from
position_units
into the internal unit
increments
(65536 increments equal 1 revolution). It consists of
numerator and denominator.
Fig. 6.3: Overview: Factor group