6. Setting Parameters
76
Festo P.BE-CMMP-CO-SW-EN 0708NH
Device type
Value
CMMP-AS-C2-3A
5000
CMMP-AS-C5-3A
10000
CMMP-AS-C5-11A-P3
7500
CMMP-AS-C10-11A-P3
15000
Due to the power derating, other values may be displayed,
depending on the controller cycle time and the final stage cycle
frequency.
6.5
Current Regulator and Motor Adjustment
Caution
Incorrect settings of the current regulator parameters and current
limits can
destroy
the
motor
and, possibly, also the
motor
controller
within a very short time!
6.5.1
Overview
The parameter set of the motor controller must be adapted for the connected motor and
the set of cables used. Affected are the following parameters:
Nominal current
dependent on the motor
Overload capacity
dependent on the motor
Number of pins
dependent on the motor
Current Control
dependent on the motor
Direction
of rotation
dependent on the motor and on the phase sequence in the motor
and angle transmitter cable
Offset angle
dependent on the motor and on the phase sequence in the motor
and angle transmitter cable
These data must be determined the first time a motor type is used with the parameteri-
sation software. For the Festo motor series EMMS-AS, you will find the parameter sets on
your installation CD. You will find additional parameter sets in the Internet under
www.festo.com/download.
Please note that the direction of rotation and offset angle also depend on the set of cables
used. The parameter sets therefore work only with identical cabling.