6. Setting Parameters
Festo P.BE-CMMP-CO-SW-EN 0708NH
121
Sub-index
01
h
Description
sample_mode
Data Type
UINT16
Access
rw
PDO Mapping
no
Units
--
Value Range
0 … 1, see table
Default Value
0
Value
Description
0
Continuous sampling
1
Autolock sampling
The following object shows a new sample event.
Sub-index
02
h
Description
sample_status
Data Type
UINT8
Access
ro
PDO Mapping
yes
Units
--
Value Range
0 … 3, see table
Default Value
0
Bit
Value
Name
Manual
0
01
h
falling_edge_occurred
= 1: New sample position (falling edge)
1
02
h
rising_edge_occurred
= 1: New sample position (rising edge)
The following object can be used to establish the bits of the object
sample_status
, which
should also result in setting bit 15 of the
statusword
. As a result, the information "Sample
event occurred" is present in the
statusword
, which normally has to be transmitted
anyway, so the controller has to read the object
sample_status
only in this case to
determine, if applicable, which edge has appeared.
Sub-index
03
h
Description
sample_status_mask
Data Type
UINT8
Access
rw
PDO Mapping
yes
Units
--
Value Range
0 … 1, see table
Default Value
0
Содержание CMMP Series