8. Operating modes
Festo P.BE-CMMP-CO-SW-EN 0708NH
189
Object 2074
h
: velocity_actual_value_filtered
A filtered velocity feedback value can be read out via the object
velocity_actual_value_filtered
, but it can only be used for display purposes. In contrast to
velocity_actual_value, velocity_actual_value_filtered
is used not for control, but for turn-
through protection of the controller. The filter time constant can be set via the object
2073
h
(
velocity_display_filter_time
). See chapter 6.6.2, Object 2073
h
.
Index
2074
h
Name
velocity_actual_value_filtered
Object code
VAR
Data Type
INT32
Access
ro
PDO Mapping
yes
Units
speed units
Value Range
--
Default Value
--
Filter
Filter
[speed units]
velocity_actual_value
(606Ch)
[speed units]
velocity_actual_value_filtered
(2074h)
velocity_display_filter_time
(2073h)
velocity_control_filter_time
(60F9h_04h)
internal velocity
value
Fig. 8.23: Determintation of
velocity_actual_value
and
velocity_actual_value_filtered
Содержание CMMP Series