![Festo CMMP Series Скачать руководство пользователя страница 104](http://html1.mh-extra.com/html/festo/cmmp-series/cmmp-series_manual_2283112104.webp)
6. Setting Parameters
104
Festo P.BE-CMMP-CO-SW-EN 0708NH
Sub-index
03
h
Description
encoder_x2b_divisor
Data Type
INT16
Access
rw
PDO Mapping
no
Units
--
Value Range
1 … 32767
Default Value
1
Sub-index
04
h
Description
encoder_x2b_counter
Data Type
UINT32
Access
ro
PDO Mapping
yes
Units
Increments (4 * resolution)
Value Range
0 … (encoder_x2b_resolution -1)
Default Value
--
Object 2025
h
: encoder_x10_data_field
The record
encoder_X10_data_field
collects parameters necessary for operation of the
incremental input X10B. Here, a digital incremental encoder or emulated incremental
signals, such as of another CMMP, can optionally be connected. The input signals over
X10 can be used optionally as command value or as feedback value. More on this can be
found in chapter 6.11.
In the object
encoder_X10_resolution
must be specified how many increments are
generated by the encoder per revolution. This equals four times the resolution. The object
encoder_X10_counter
delivers the currently counted number of increments (between 0
and the set number or increments -1).
With the object
encoder_X10_numerator
and
encoder_X10_divisor
, a possible gear
(also with algebraic sign) can be considered.
If the X10 signal is used as feedback value, this would be a gear between the motor and
the feedback value encoder connected to X10, which is mounted at the drive-out. When
the X10 signal is used as command value, gear transmissions between master and slave
can be implemented.
Index
2025
h
Name
encoder_x10_data_field
Object code
RECORD
No. of Elements 4
Содержание CMMP Series
Страница 2: ......