6. Setting Parameters
116
Festo P.BE-CMMP-CO-SW-EN 0708NH
Sub-index
02
h
Description
dig_out_state_mapp_dout_2
Data Type
UINT8
Access
rw
PDO Mapping
no
Units
--
Value Range
0 … 16, see table
Default Value
0
Sub-index
03
h
Description
dig_out_state_mapp_dout_3
Data Type
UINT8
Access
rw
PDO Mapping
no
Units
--
Value Range
0 … 16, see table
Default Value
0
Value Description
0
Off (output is low)
1
Position X
command
= X
target
2
Position X
feedback
= X
target
3
Reserved
4
Remaining path
5
Homing run active
6
Comparison speed reached
7
I²t monitoring active
8
Drag error
9
Low voltage intermediate circuit
10
Locking brake vented
11
Final stage active
12
On (output is high)
13
Reserved
14
Reserved
15
Linear motor identified
16
Homing position valid