7. Device control
Festo P.BE-CMMP-CO-SW-EN 0708NH
139
Caution
Final stage blocked…
…means that the power semiconductors (transistors) can no longer
be actuated. If this condition is taken with a turning motor, it fizzles
out unbraked. If a mechanical motor brake is present, it is
automatically triggered.
The signal does not guarantee that the motor is really voltage-free.
Caution
Final stage enabled…
…means that the motor is actuated and regulated according to the
chosen operating mode. If a mechanical motor brake is present, it
is automatically triggered. In case of a defect or incorrect
parameterisation (motor current, number of poles, resolver offset
angle, etc.), this can result in uncontrolled behaviour of the drive.
7.1.3
Controlword (control word)
Object 6040
h
: controlword
With the
controlword
, the current condition of the motor controller can be changed or a
certain action (e.g. start of reference travel) can be directly triggered. The function of bits
4, 5, 6 and 8 depends on the current operating mode (
modes_of_operation
) of the motor
controller, which is explained after this chapter.
Index
6040
h
Name
controlword
Object code
VAR
Data Type
UINT16
Access
rw
PDO Mapping
yes
Units
--
Value Range
--
Default Value
0