8. Operating modes
Festo P.BE-CMMP-CO-SW-EN 0708NH
179
Object 60C3
h
: interpolation_sync_definition
The object
interpolation_sync_definition
sets the type (
synchronize_on_group
) and
number of (
ip_sync_every_n_event
) of synchronisation telegrams per synchronisation
interval. For the CMMP series, only the standard SYNC telegram and 1 SYNC per interval
can be set.
Index
60C3
h
Name
interpolation_sync_definition
Object code
ARRAY
No. of Elements 2
Data Type
UINT8
Sub-index
01
h
Description
syncronize_on_group
Access
rw
PDO Mapping
yes
Units
--
Value Range
0
Default Value
0
Value
Meaning
0
use Standard SYNC telegram
Sub-index
02
h
Description
ip_sync_every_n_event
Access
rw
PDO Mapping
yes
Units
--
Value Range
1
Default Value
1
Object 60C4
h
: interpolation_data_configuration
The object record
interpolation_data_configuration
can be used to configure the type
(
buffer_organisation
) and size (
max_buffer_size, actual_buffer_size
) of any buffer
present as well as access to it (
buffer_position, buffer_clear
). The size of a buffer element
can be read out via the object
size_of_data_record
. Although no buffer is available for the
interpolation type "Linear interpolation without buffer"‚ access via the object
buffer_clear
must still be enabled in this case as well.