6. Setting Parameters
Festo P.BE-CMMP-CO-SW-EN 0708NH
83
Object 6510
h
_ 2F
h
: max_motor_temperature
If the motor temperature defined in this object is exceeded, a reaction occurs in
accordance with Error management (error 3-0, Excess temperature in motor analogue).
If a reaction is parameterised that results in shutting down the drive, an emergency
message is sent.
For parameterisation of the error management, see chapter 6.18.
Sub-index
2F
h
Description
max_motor_temperature
Data Type
INT16
Access
rw
PDO Mapping
no
Units
°C
Value Range
20 … 300
Default Value
100
Object 60F6
h
: torque_control_parameters
The data of the current controller must be taken from the parameterisation software.
Attention must be paid to the following calculations:
The amplification of the current controller must be multiplied by 256. With an
amplification of 1.5 in the "Current Controller" menu of the parameterisation software,
the value 384 = 180
h
must be written in the object
torque_control_gain
.
The current controller time constant is specified in the parameterisation software in
milliseconds. To transfer this time constant into the
torque_control_time
object, it must
previously be converted into microseconds. With a specified time of 0.6 milliseconds, the
corresponding value 600 is entered in the object
torque_control_time.
Index
60F6
h
Name
torque_control_parameters
Object code
RECORD
No. of Elements 2
Sub-index
01
h
Description
torque_control_gain
Data Type
UINT16
Access
rw
PDO Mapping
no
Units
256 = “1“
Value Range
0 … 32 * 256
Default Value
3 * 256 (768)