6. Setting Parameters
Festo P.BE-CMMP-CO-SW-EN 0708NH
113
Sub-index
03
h
Description
analog_input_offset_ch_2
Access
rw
PDO Mapping
no
Units
mV
Value Range
-10000 … 10000
Default Value
0
6.13
Digital inputs and outputs
6.13.1
Overview
All digital inputs of the motor controller can be read via the CAN bus, and almost all digital
outputs can be set as desired. Moreover, status messages can be assigned to the digital
outputs of the motor controller.
6.13.2
Description of the Objects
Objects treated in this chapter
Index
Object
Name
Type
Attr.
60FD
h
VAR
digital_inputs
UINT32
ro
60FE
h
ARRAY
digital_outputs
UINT32
rw
2420
h
RECORD
digital_output_state_mapping
ro
2420
h
_01
h
VAR
dig_out_state_mapp_dout_1
UINT8
rw
2420
h
_02
h
VAR
dig_out_state_mapp_dout_2
UINT8
rw
2420
h
_03
h
VAR
dig_out_state_mapp_dout_3
UINT8
rw
Object 60FD
h
: digital_inputs
The digital outputs can be triggered via the object
60FD
h
.
Index
60FD
h
Name
digital_inputs
Object code
VAR
Data Type
UINT32
Access
ro
PDO Mapping
yes
Units
--
Value Range
according to table below
Default Value
0