8. Operating modes
Festo P.BE-CMMP-CO-SW-EN 0708NH
195
8.7
Torque Regulation Operating Mode
(Profile Torque Mode)
8.7.1
Overview
This chapter describes torque-controlled operation. This operating mode allows an
external torque nominal value
target_torque
, which can be smoothed using the integrated
ramp generator, to be specified for the motor controller. It is thus possible for this motor
controller to also be used for path control, with which both the position controller and the
velocity controller are displaced to an external computer.
Fig. 8.25: Structure of torque-regulated operation