6. Setting Parameters
118
Festo P.BE-CMMP-CO-SW-EN 0708NH
Object 6510
h
_ 12
h
: limit_switch_selector
With the object
6510
h
_ 12
h
(
limit_switch_selector
), the assignment of the limit switches
(negative, positive) can be exchanged without having to change the cabling. Enter a one
to exchange the assignment of the limit switches.
Sub-index
12
h
Description
limit_switch_selector
Data Type
INT16
Access
rw
PDO Mapping
no
Units
--
Value Range
0, 1
Default Value
0
Value
Meaning
0
DIN6 = E0 (limit switch negative)
DIN7 = E1 (limit switch positive)
1
DIN6 = E1 (limit switch positive)
DIN7 = E0 (limit switch negative)
Tab. 6.1: Please insert description of table
Object 6510
h
_ 14
h
: homing_switch_polarity
The polarity of the homing switch can be programmed through the object
6510
h
_ 14
h
(
homing_switch_polarity
). A "0" is entered in this object for an opening homing switches,
a "1" when closing contacts are used.
Sub-index
14
h
Description
homing_switch_polarity
Data Type
INT16
Access
rw
PDO Mapping
no
Units
--
Value Range
0, 1
Default Value
1
Value
Meaning
0
Normally closed contact
1
N/O contact