6. Setting Parameters
Festo P.BE-CMMP-CO-SW-EN 0708NH
99
Sub-index
01
h
Description
limit_current_input_channel
Data Type
UINT8
Access
rw
PDO Mapping
no
Units
--
Value Range
0 … 4
Default Value
0
Sub-index
02
h
Description
limit_current
Data Type
INT32
Access
rw
PDO Mapping
no
Units
mA
Value Range
--
Default Value
0
Value
Meaning
0
No limitation
1
AIN0
2
AIN1
3
AIN2
4
Field bus (selector B)
Object 2416
h
: speed_limitation
The maximum speed of the motor can be limited with the object group
speed_limitation
in the operating mode profile_torque_mode; this makes a speed-limited torque operation
possible. The command value source of the limit speed is specified via the object
limit_speed_input_channel
. Here, a choice can be made between specification of a direct
command value (fixed value)
or specification via an analogue input. Depending on the
source chosen, either the limit torque (fixed value) or the scaling factor for the analogue
inputs (source = analogue input) is specified via the object
limit_speed
. In the first case,
the specified speed is limited directly; in the second case, the speed that should
correspond to a voltage of 10 V is specified.