6. Setting Parameters
102
Festo P.BE-CMMP-CO-SW-EN 0708NH
With the object
encoder_x2a_numerator
and
encoder_x2a_divisor
a possible gear
(also with algebraic sign) between
motor shaft and encoder
can be considered.
Index
2024
h
Name
encoder_x2a_data_field
Object code
RECORD
No. of Elements 3
Sub-index
01
h
Description
encoder_x2a_resolution
Data Type
UINT32
Access
ro
PDO Mapping
no
Units
Increments (4 * resolution)
Value Range
--
Default Value
65536
Sub-index
02
h
Description
encoder_x2a_numerator
Data Type
INT16
Access
rw
PDO Mapping
no
Units
--
Value Range
-32768 … 32767 (except 0)
Default Value
1
Sub-index
03
h
Description
encoder_x2a_divisor
Data Type
INT16
Access
rw
PDO Mapping
no
Units
--
Value Range
1 … 32767
Default Value
1