6. Setting Parameters
128
Festo P.BE-CMMP-CO-SW-EN 0708NH
Object 6510
h
_ AC
h
: firmware_type
The object
firmware_type
is used to read out which device family and angle encoder type
the loaded firmware is suitable for. Since for the CMMP family the angle encoder interface
is no longer pluggable actual, all bits are set in the parameter G (F
h
).
Sub-index
AC
h
Description
firmware_type
Data Type
UINT32
Access
ro
PDO Mapping
no
Units
000000GX
h
Value Range
00000F2
h
Default Value
00000F2
h
Value (x)
Meaning
0
h
IMD-F
1
h
CMMP-AS
2
h
CMMP-AS-C2-3A
Object 6510
h
_ B0
h
: cycletime_current_controller
The cycle time in microseconds of the current controller can be read out via the object
cycletime_current_controller
.
Sub-index
B0
h
Description
cycletime_current_controller
Data Type
UINT32
Access
ro
PDO Mapping
no
Units
µs
Value Range
--
Default Value
00000068
h