8. Operating modes
Festo P.BE-CMMP-CO-SW-EN 0708NH
193
The object group
velocity_ramps
exists so these 4 accelerations can be individually
parameterised. Care should be taken that the objects
profile_acceleration
and
profile_deceleration
change the same internal accelerations as the
velocity_ramps
.
If the
profile_acceleration
is written,
velocity_acceleration_pos
and
velocity_
acceleration_neg
are changed together; if the
profile_deceleration
is written,
velocity_deceleration_pos
and
velocity_deceleration_neg
are changed together.
Object
velocity_ramps_enable
determines whether or not the command values are led
over the ramp generator.
Index
2090
h
Name
velocity_ramps
Object code
RECORD
No. of Elements 5
Sub-index
01
h
Description
velocity_ramps_enable
Data Type
UINT8
Access
rw
PDO Mapping
no
Units
..
Value Range
0: Command value NOT over the ramp generator
1: Command value over the ramp generator
Default Value
1
Sub-index
02
h
Description
velocity_acceleration_pos
Data Type
INT32
Access
rw
PDO Mapping
no
Units
acceleration units
Value Range
..
Default Value
14100 min
-1
/s
Sub-index
03
h
Description
velocity_deceleration_pos
Data Type
INT32
Access
rw
PDO Mapping
no
Units
acceleration units
Value Range
..
Default Value
14100 min
-1
/s
Содержание CMMP Series