6. Setting Parameters
Festo P.BE-CMMP-CO-SW-EN 0708NH
71
Sub-index
3A
h
Description
enable_enhanced_modulation
Data Type
UINT16
Access
rw
PDO Mapping
no
Units
--
Value Range
0, 1
Default Value
0
Value
Meaning
0
Extended sinus modulation OFF
1
Extended sinus modulation ON
Activation of the extended sinus modulation only becomes
effective after a reset. The parameter set must first be stored
(
save_all_parameters
) and then a reset performed.
Object 6510
h
_ 31
h
: power_stage_temperature
The temperature of the final stage can be read out via the object
power_stage_temperature
. When the temperature specified in the object
6510
h
_ 32
h
(
max_power_stage_temperature
) is exceeded, the final stage shuts off and an error
message is issued.
Sub-index
31
h
Description
power_stage_temperature
Data Type
INT16
Access
ro
PDO Mapping
yes
Units
°C
Value Range
--
Default Value
..
Содержание CMMP Series