8. Operating modes
Festo P.BE-CMMP-CO-SW-EN 0708NH
183
Fig. 8.21: Synchronisation and data release
No. Event
CAN Object
1
Generate SYNC message
2
Request of the ip operating mode
6060
h
, modes_of_operation = 07
3
Wait until operating mode is taken
6061
h
, modes_of_operation_display = 07
4
Reading out the current actual position
6064
h
, position_actual_value
5
Writing back as current nominal position
60C1
h
_01
h
, ip_data_position
6
Start of interpolation
6040
h
, controlword, enable_ip_mode
7
Acknowledgement by motor controller
6041
h
, statusword, ip_mode_active
8
Changing the current nominal position in accordance
with trajectory
60C1
h
_01
h
, ip_data_position
After the synchronous travel process is ended, deletion of the bit
enable_ip_mode
prevents further evaluation of position values. Then the system can switch into another
operating mode, if necessary.