8. Operating modes
Festo P.BE-CMMP-CO-SW-EN 0708NH
155
Value
Meaning
1
Profile Position Mode (position controller with positioning mode)
3
Profile Velocity Mode (velocity controller with nominal value ramp)
4
Torque Profile Mode (torque regulator with nominal value ramp)
6
Homing Mode (reference travel)
7
Interpolated position mode
The current operating mode can only be read in the object
modes_of_operation_display
!
Since a change in operating mode can take some time, one
must
wait until the newly selected mode appears in the object
modes_of_operation_display
.
Object 6061
h
: modes_of_operation_display
In the object
modes_of_operation_display
, the current operating mode of the motor
controller can be read. If an operating mode is set via the object
6060
h
, besides the actual
operating mode, the nominal value activations (nominal value selector) needed for
operation of the motor controller under CANopen must also be made. These are:
Selector
Profile velocity mode
Profile torque mode
A
Velocity command value (field bus 1)
Torque command value (field bus 1)
B
Torque limitation, if necessary
inactive
C
Velocity command value (synchronous velocity)
inactive
In addition, the command value ramp is always switched on. Only if these activations are
set in the stated way will one of the CANopen operating modes be returned. If these
settings are changed, for example, with the parameterisation software, a respective
"user" operating mode is returned to show that the selectors have been changed.
Index
6061
h
Name
modes_of_operation_display
Object code
VAR
Data Type
INT8
Access
ro
PDO Mapping
yes
Units
--
Value Range
see table
Default Value
3
Содержание CMMP Series
Страница 2: ......