5. Access Procedure
Festo P.BE-CMMP-CO-SW-EN 0708NH
45
Error_code (hex) Display
Meaning
8083
E 43 2
Limit switches: Positioning suppressed
8084
E 45 0
Driver supply cannot be switched off
8085
E 45 1
Driver supply cannot be activated
8086
E 45 2
Driver supply has been activated
7580
E 60 0
Ethernet I
7581
E 61 0
Ethernet II
F080
E 80 0
Overflow current controller - IRQ
F081
E 80 1
Overflow speed controller - IRQ
F082
E 80 2
Overflow position controller- IRQ
F083
E 80 3
Overflow interpolator - IRQ
F084
E 81 4
Iverflow low level - IRQ
F085
E 81 5
Overflow MDC - IRQ
5080
E 90 x
Hardware fault
6000
E 91 0
Internal initialisation error
5.5.3
Description of the Objects
Object 1003
h
: pre_defined_error_field
The respective
error_code
of the error messages is also stored in a four-stage fault
memory. This is structured like a shift register, so that the last occurring error is always
stored in the object
1003
h
_ 01
h
(
standard_error_field_0
). Through read access onto the
object
1003
h
_ 00
h
(
pre_defined_error_field
), it can be determined how many error
messages are currently stored in the fault memory. The fault memory is deleted by writing
the value 00h into the object
1003
h
_ 00
h
(
pre_defined_error_field
). To be able to
reactivate the final stage of the motor controller after an error, an
error acknowledgement
(see chapter 7.1: Change of State 15) must also be performed.
Index
1003
h
Name
pre_defined_error_field
Object code
ARRAY
No. of Elements 4
Data Type
UINT32