6. Setting Parameters
Festo P.BE-CMMP-CO-SW-EN 0708NH
97
Object 6510
h
_ 20
h
: position_range_limit_enable
The range limits defined by the object
607B
h
can be activated via the object
position_range_limit_enable
. Various modes are possible:
If the "Shortest path" mode is chosen, positionings are always carried out on the
physically shorter section. The drive itself adapts the algebraic sign of the travel speed.
In the two modes "Fixed direction of rotation", positioning always takes place only in the
direction specified in the mode.
Index
6510
h
Name
drive_data
Object code
RECORD
No. of Elements 51
Sub-index
20
h
Description
position_range_limit_enable
Data Type
UINT16
Access
rw
PDO Mapping
no
Units
--
Value Range
0 … 5
Default Value
0
Value
Meaning
0
Off
1
Shortest path (for compatibility reasons)
2
Shortest path
3
Reserved
4
Fixed direction of rotation "positive"
5
Fixed direction of rotation "negative"
Object 2030
h
: set_position_absolute
With the object
set_position_absolute
, the readable actual position can be moved
without changing the physical location. The drive does not carry out any movement.
If an absolute encoder system is connected, the position change is stored in the encoder if
the encoder system permits this. The position change is kept in this case, that is, after a
reset. This save operation runs in the background regardless of this object. Likewise, all
parameters belonging to the encoder storage are stored with their current values.
Содержание CMMP Series