6. Setting Parameters
54
Festo P.BE-CMMP-CO-SW-EN 0708NH
6.
Setting Parameters
Before the motor controller can carry out the desired task (torque regulation, RPM
regulation, positioning), numerous parameters of the motor controller must be adapted to
the motor used and the specific application. The sequence in the subsequent chapters
should be followed thereby. After setting of the parameters, device control and use of the
various operating modes are explained.
The display of the motor controller shows an "A" (Attention) if the
motor controller has not been properly parameterised yet. If the
motor controller is to be completely parameterised via CANopen,
you must write in the object
6510
h
_ C0
h
to suppress this display.
(See page 130 , Object 6510h _ C0h: commissioning_state).
Besides the parameters described in depth here, the object directory of the motor
controller contains other parameters that have to be implemented in accordance with
CANopen. But they normally do not contain any information that can sensibly be used in
designing an application with the CMMP family. If needed, specification of such objects
can be read in [1] and [2] (see page 10).
6.1
Load and Save Parameter Sets
6.1.1
Overview
The motor controller has three parameter sets:
-
Current parameter set
This parameter set is located in the random access memory (RAM) of the motor
controller. It can be read and written on as desired with the parameterisation software
or via the CAN bus. When the motor controller is switched on, the
application
parameter set is copied
into the
current parameter set.
-
Default parameter set
This is the parameter set of the motor controller provided standard by the
manufacturer and is unchangeable. Through a write process into the CANopen object
1011
h
_ 01
h
(
restore_all_default_parameters
), the
default parameter set can be
copied
into the
current parameter set
. This copying process is only possible when the
final stage is switched off.
-
Application parameter set
The
current parameter set
can be stored in the nonvolatile flash memory. The storage
process can be triggered with a read access to the CANopen object
1010
h
_ 01
h
(
save_all_parameters
). When the motor controller is switched on, the
application
parameter set
is automatically copied into the
current parameter set
.