Multi-Console
541
RPU and console
One RPU and one console can be used as a backup option. In this configuration, it is
recommended that you set the RPU as the primary and the console as the backup. In this
scenario, should the RPU go offline, you will still have the full functionality of the console user-
interface at your disposal.
RPU and RPU
Two RPUs may serve as primary and backup also. A backup system of this type can support
many client consoles at once, which you may turn on and off as needed without the need to
reset to a different master each time.
This application is ideal for permanent installations requiring synchronized backup.
Remote Software Installation
Within a multi-console system, you can remotely install software to all devices.
Note:
All devices must be upgraded to version 1.9 before remote software
installation is available.
In the ECU, go to Setting> General> Automatically Update Software to enable. Once
enabled, the devices can be remotely updated with the next version of software. Devices will
receive the software update from the Primary. When you install software on the Primary, the
software will first be copied to its hard drive.
With the devices synchronized with the Primary, install the new version of software onto the
Primary. All devices will lose their connection with the Primary at that time. When the Primary
comes back online after installing the software, all the connected devices will be forced to
update their software before they can reconnect with the Primary.
Remote Power On/Off
In a multi-console system, it is possible to power on and off devices remotely. Remote Power
On and Remote Power Off must be enabled on each device before it can receive the power on
and off commands. In the ECU go to Settings> Network> Enable Remote Power Off and
Enable Remote Power On. The default setting for both is “Disabled”.
Note:
Original Eos consoles cannot be remotely powered on.
The Remote Power commands are sent from the browser. The command for Power On is sent
from Browser> Network> Power On MultiConsole System, and the command for Power Off is
from Browser> Network> Power Off MultiConsole System.
Note:
Only devices that synchronize with the Primary will be available for Remote
Power On and Off.
Mirror Mode
Mirror Mode is used to mirror the displays of another device. When a device is in mirror mode,
the only action allowed from that device is paging via the page keys and shut down/start up.
When a device in mirror mode pages, it also pages the host.
Содержание Element Classic
Страница 1: ...Ion Classic User Manual Version 3 1 1 4310M1210 3 1 1 RevA 2022 03...
Страница 92: ...78 Ion Classic User Manual...
Страница 212: ...198 Ion Classic User Manual...
Страница 274: ...260 Ion Classic User Manual...
Страница 275: ...Mark 261 Chapter 9 Mark About Mark 262 AutoMark 262 Referenced Marks 263...
Страница 308: ...294 Ion Classic User Manual...
Страница 346: ...332 Ion Classic User Manual...
Страница 364: ...350 Ion Classic User Manual...
Страница 378: ...364 Ion Classic User Manual...
Страница 384: ...370 Ion Classic User Manual...
Страница 426: ...412 Ion Classic User Manual...
Страница 438: ...424 Ion Classic User Manual...
Страница 444: ...430 Ion Classic User Manual...
Страница 450: ...436 Ion Classic User Manual...
Страница 458: ...444 Ion Classic User Manual...
Страница 479: ...Magic Sheets 465...
Страница 480: ...466 Ion Classic User Manual...
Страница 530: ...516 Ion Classic User Manual...
Страница 558: ...544 Ion Classic User Manual...
Страница 578: ...564 Ion Classic User Manual...