Fan
259
•
[1] [Thru] [5] [At] [1] <0> [Thru] [3] <0> {Fan} {Mirror} [Enter] - sets channel 1 to 30%,
2 to 20%, 3 to 10%, 4 to 20%, and 5 to 30%.
Fanning References
When fanning references, such as palettes, if there are more than 2 reference lists are used
then the data will be referenced data. The fan will be repeated if there are more channels than
references.
•
[1] [Thru] [5] [Int Palette] [1] [Thru] [3] [Enter] - sets channel 1 to IP1, 2 to IP2, 3 to IP3,
4 to IP1, and 5 to IP2.
If the list contains 2 or less references, fan will be set to the levels between the references as
absolute data.
•
[1] [Thru] [5] [Int Palette] [1] [Thru] [2] [Enter] - (Intensity palette 1 is all channels at 0%
and Intensity palette 2 is all channels set to 100%.) sets channel 1 to 0%, 2 to 25%, 3 to
50%, 4 to 75%, and 5 to 100% as absolute data.
Fanning Timing and Delays
Fanning timing and delays work exactly like fanning parameters.
•
[1] [Thru] [5] [Time] [6] [Thru] [1] [0] [Enter] - sets the discrete times for channel 1 to 6
seconds, 2 to 7 seconds, 3 to 8 seconds, 4 to 9 seconds, and 5 to 10 seconds.
•
[Cue] [1] [Thru] [5] [Time] [6] [Thru] [1] [0] [Enter] - sets the times for cue 1 to 6
seconds, 2 to 7 seconds, 3 to 8 seconds, 4 to 9 seconds, and 5 to 10 seconds.
•
[Cue] [1] [Part] [1] [Thru] [3] [Time] [6] [Thru] [8] [Enter] - sets the times for cue 1's
parts to part 1 to 6 seconds, part 2 to 7 seconds, and part 3 to 8.
•
[1] [Thru] [5] [Delay] [6] [Thru] [8] {Fan} {Mirror} [Enter] - sets the discrete delays of
channel 1 to 8 seconds, 2 to 7 seconds, 3 to 6 seconds, 4 to 7 seconds, and 5 to 8
seconds.
Using Subgroups with Fan
can be used with the Fan feature. Channels in the same subgroup
will act as a single channel when fanned.
Example:
Group 1 is made up of channels 120 thru 130. Channels 120 thru 123 are one
subgroup, channels 124 thru 126 are not in any subgroup, and channels 127
thru 130 are another subgroup.
•
[Group] [1] {Fan} [Enter]
Selects group 1 and puts it into fan mode. Rolling up the level wheel creates
the following result. Channels 120 thru 123 share an intensity, channels 124
thru 126 each have different intensities, and channels 127 thru 130 share an
intensity.
Содержание Element Classic
Страница 1: ...Ion Classic User Manual Version 3 1 1 4310M1210 3 1 1 RevA 2022 03...
Страница 92: ...78 Ion Classic User Manual...
Страница 212: ...198 Ion Classic User Manual...
Страница 274: ...260 Ion Classic User Manual...
Страница 275: ...Mark 261 Chapter 9 Mark About Mark 262 AutoMark 262 Referenced Marks 263...
Страница 308: ...294 Ion Classic User Manual...
Страница 346: ...332 Ion Classic User Manual...
Страница 364: ...350 Ion Classic User Manual...
Страница 378: ...364 Ion Classic User Manual...
Страница 384: ...370 Ion Classic User Manual...
Страница 426: ...412 Ion Classic User Manual...
Страница 438: ...424 Ion Classic User Manual...
Страница 444: ...430 Ion Classic User Manual...
Страница 450: ...436 Ion Classic User Manual...
Страница 458: ...444 Ion Classic User Manual...
Страница 479: ...Magic Sheets 465...
Страница 480: ...466 Ion Classic User Manual...
Страница 530: ...516 Ion Classic User Manual...
Страница 558: ...544 Ion Classic User Manual...
Страница 578: ...564 Ion Classic User Manual...