342
Ion Classic User Manual
All parameter data for selected channels will be recalled, or by using the IFCB category buttons
or parameter buttons, you may recall subsets of channel data. To recall only levels and not
effect, timing, mark or other non-level data, use the {Only Levels} softkey.
To recall data from only the active channels, use the {Only Active} softkey.
In Live, you can use [Sneak] with [Recall From] to fade in the change.
Below are some examples of recall commands from record targets:
•
[2] [Recall From] [Cue] [5] [Enter] - recalls all recorded data from cue 5 for channel 2.
•
[2] [-] {Focus} [Recall From] [Cue] [5] [Enter] - recalls all data for channel 2 from cue 5,
except focus (pan/tilt - XYZ) data.
•
[Group] [3] {Color} {Focus} [Recall From] [Preset] [6] [Enter] - recalls the color and focus
information from preset 6 for the channels in group 3. Could also be used with a
channel selection set instead of a group.
•
[Group] [3] {Color} [Recall From] [Cue] [7] {Make Absolute} [Enter] - recalls color data
for group 3 from cue 7 and breaks any references to record targets.
•
[2] [Recall From] [Sub] [4] [Enter] - recalls all recorded parameter data from sub 4 for
channel 2.
•
[Recall From] [Intensity Palette] [1]- recalls all of the values stored in intensity palette 1.
•
[1][0] [Recall From] [Cue] [2] [Sneak] <Time> 7 [Enter] - would recall the recorded data
that cue 2 has for channel 10 and sneak it in 7 seconds when used in live.
•
[Recall From] [Cue] [1][0] {Only Active} [Enter] - recalls data from only the active
channels, which are those channels with intensities above 0, if no channel selection had
been previously made.
•
[Recall From] [Cue] [2] [Enter] - would result in a selection of the channels used in that
cue and their values. Any channels that are used in the cue list but do not currently have
an intensity in the recalled from cue will be set to zero. Pressing [At] afterwards would
post a numeric list of those channels to the command line.
In Live or Blind, hitting [Recall From] [Recall From] will put [Recall From] [Cue] on the
command line.
Using the {HTP} softkey with [Recall From] will cause any intensity levels to be ignored if they
are less than or equal to the recalled value.
Example:
Channels 1 and 2 are at 50% in cue 10, and in cue 11 channel 1 is at 10%
and channel 2 is at full. If you are in cue 10, and use the syntax:
•
[Recall From] [Cue] [1][1] {HTP} [Enter]
Channel 1 will remain at 50% and channel 2 will go to full.
Recall From Park
You can use [Recall From] [Park] to set a channel or parameter to the same level as the current
park value.
Example:
Channels 1 through 5 are parked at 55. To recall that level to channels in live
or blind, use the following syntax:
•
[1] [Thru] [1][5] [Recall From] [Park] [Enter]
Channels 1 through 5 will be set to 55 and channels 6 through 15 will be
unaffected.
Содержание Element Classic
Страница 1: ...Ion Classic User Manual Version 3 1 1 4310M1210 3 1 1 RevA 2022 03...
Страница 92: ...78 Ion Classic User Manual...
Страница 212: ...198 Ion Classic User Manual...
Страница 274: ...260 Ion Classic User Manual...
Страница 275: ...Mark 261 Chapter 9 Mark About Mark 262 AutoMark 262 Referenced Marks 263...
Страница 308: ...294 Ion Classic User Manual...
Страница 346: ...332 Ion Classic User Manual...
Страница 364: ...350 Ion Classic User Manual...
Страница 378: ...364 Ion Classic User Manual...
Страница 384: ...370 Ion Classic User Manual...
Страница 426: ...412 Ion Classic User Manual...
Страница 438: ...424 Ion Classic User Manual...
Страница 444: ...430 Ion Classic User Manual...
Страница 450: ...436 Ion Classic User Manual...
Страница 458: ...444 Ion Classic User Manual...
Страница 479: ...Magic Sheets 465...
Страница 480: ...466 Ion Classic User Manual...
Страница 530: ...516 Ion Classic User Manual...
Страница 558: ...544 Ion Classic User Manual...
Страница 578: ...564 Ion Classic User Manual...