Proservo NMS5
68
Hauser
Operation Input
2 photo couplers, for external input from controller (tumbler switch,
DCS, etc.)
Operation output logic
Input voltage
15VDC, active circuit (supplied by NMS5)
Input current
Approximately 5mA
Gauge Status
CTR1
CTR2
LEVEL
UP
STOP
INTERFACE
LEVEL
0 (OFF)
1 (ON)
0 (OFF)
1 (ON)
0 (OFF)
0 (OFF)
1 (ON)
1 (ON)
7 Commissioning