Proservo NMS5
Hauser
123
50
Matrix group
Function group
Item
Access
code
Short description
Default value
Set
Select
Display
Possible settings,
selection, or display
Index No,
GVH
CALIBRATION
UPPER STOP
Set upper limit of displacer movement during normal operation.
0 - 99999.9 mm
160
51
164
51
16000 mm
Set
163
50
0 mm
Set
0 - 99999.9 mm
162
50 g
Set
Set
ADJUSTMENT
LOWER STOP
350 g
Set
0 - 999 g
UNDER TENS. SET
SLOW HOIST
60 mm
51
10 s
Set
10 - 999 sec.
167
Set lower limit of displacer movement during normal operation.
161
OVER TENS. SET
51
Set this value such that if G3V7H0 Measured Weight of displacer
equals or exceeds setting at G1V6H2, motor will freeze.
Increase this parameter if necessary in high viscosity liquids.
Caution!:
Magnetic coupling disconnects above 800 grams tension.
Set this value such that if G3V7H0 Measured Weight of displacer
equals or is less than setting at G1V6H3, motor will freeze.
Decrease this parameter if necessary in high viscosity liquids.
0 - 999 g
Displacer will enter slow speed hoist according to this value,
useful if displacer contacts with narrow valves.
60 - 1800 mm
DISPL. RAIS. REP.
Set the distance to raise displacer above liquid surface during
repeatability test.
10 mm
Set
10 - 99 mm
165
DISPL. WAIT REP.
51
Set the waiting time after displacer rises above liquid surface
during repeatability test.
DISPL. WAIT DIP.
51
Used for Water Level command. Set the waiting time between
displacer balance status and return to Level.
10 s
Set
10 - 999 sec.
166
13 Matrix