Proservo NMS5
144
Hauser
Matrix group
Function group
Item
Access
code
Short description
Default value
Set
Select
Display
Possible settings,
selection, or display
Index No,
GVH
ADJ. SENSOR
Select units for temperature data displayed locally at NMS/NRF
UNIT
LEV. UNIT (HOST)
TEMP UNIT (HOST)
DEN. UNIT (HOST)
Select display units for level value data to be sent to host CPU
via remote communications
760
761
LEV. UNIT
TEMP. UNIT
DEN. UNIT
Select units for temperature value data to be sent to host CPU
via remote communications
Select display units for density value data to be sent to host CPU
via remote communications
Select units for level value data displayed locally at NMS/NRF.
Select units for density value data displayed locally at NMS/NRF
51
51
mm
°C
g/mL
51
mm
°C
g/mL
51
51
51
Select
Select
Select
Select
Select
Select
m, inch, cm, ft
°C, °F, °R, °K
Kg/m , lb/gl, SGU, Kg/l,
g/l, lb/in, st/y
3
3
m, inch, cm, ft
°C, °F, °R, °K
Kg/m , lb/gl, SGU, Kg/l,
g/l, lb/in, st/y
762
765
766
767
HART LINE
NMT
770
Select Terminal Port A (Ex ia) or Terminal Port B (Ex d) for
the NMT connection
15
Set
771
Set
772
Set
INTERFACE ADJUST
BALANCE COUNT
IF 2 OFFSET
777
780
781
782
783
784
HART DEVICE (1)
HART DEVICE (2)
777
777
51
Set Volume Tolerance for Balance condition during Interface
measurement
Used for Interface Measurement. Increase Brake Rate to make the
balance zone smaller and decrease interface measurement time.
ࠉ
0.0 mm
0.0 mm
Set
Display
Display
Display
Display
VOL. TOL. FOR I/F
BRAKE RATE
IF 1 OFFSET
Select Terminal Port A (Ex ia) or Terminal Port B (Ex d) for
the HART Device 1.
Select Terminal Port A (Ex ia) or Terminal Port B (Ex d) for
the HART Device 2.
51
51
51
51
Used for Interface Measurement. Balance signal is generated after
MOTORMOVEMENTCHANGESFROMFASTTOSLOWSPECIlEDNUMBEROF
times. Coordinate this setting with G2V9H9 Balance Delay setting.
Change this setting to correct Interface 1 level deviation.
Change this setting to correct Interface 2 level deviation.
TERMINAL
PORT B
TERMINAL
PORT B
TERMINAL
PORT B
TERMINAL PORT B
TERMINAL PORT A
TERMINAL PORT B
TERMINAL PORT A
TERMINAL PORT B
TERMINAL PORT A
0.3 mL
150
0 - 99.9 mL
0 - 255
0 - 255
0 - 9999.9 mm
0 - 9999.9 mm
ADJ A ZERO
ADJ A ZERO
ADJ B SP
AN
ADJ B SP
AN
530
530
530
530
Hall Sensor A Zero signal
Hall Sensor A Zero signal
Hall Sensor B Full span signal
Hall Sensor B Full span signal
Display
Display
Display
Display
740
741
742
743
ADJ. SENSOR
HAR
T ERROR RA
TE
ERR. RA
TE NRF
ERR. RA
TE NMT
ERR. RA
TE DEV(1)
ERR. RA
TE DEV(2)
530
530
530
530
Communication error rate
Communication error rate
Communication error rate
Communication error rate
Display
Display
Display
Display
750
751
752
753
13 Matrix