Proservo NMS5
Hauser
63
7.5.3
Mark/Space(M/S) Communication Board Setting
Jumper Setting
Jumper settings for M/S communication board
Polling Address Setting
Caution!
Polling addresses are set by mechanically at SW1 (1-8) and SW2(1-2) on Mark Space communication board
(not by accessing NMS programming matrix). Check all polling addresses before setting. The following table
shows address setting.
Function Setting
Each function is set at SW2-* shown as follows.
Jumper
Function
Default condition
J3 (Mode)
Use EPROM [IC4]->short
Short
J3 (Reset)
Reset
Open
J3 (WD)
Watch dog setting
Short
Switch Position
Value
SW1-1
1
SW1-2
2
SW1-3
4
SW1-4
8
SW1-5
16
SW1-6
32
SW1-7
64
SW1-8
128
SW2-1
256
SW2-2
512
Switch
Function
Default Condition
SW2-3
ON: Data transmission under unbalanced condition
ON
SW2-4
ON: low baud rate setting
OFF
SW2-5
ON: Feet data OR 0-20m, OFF: 0-30m
OFF
SW2-6
ON: Measured data converted to feet
OFF
SW2-7
ON: Temperature data (57 bits)
ON
SW2-8
ON: Deg. F measured temperature unit, OFF: Deg. C
OFF
ON
1
2
3
4
5
6
7
8
ON
1
2
3
4
5
6
7
8
SW - 1
SW - 2
Address Setting
Function Setting
Setting Example (example above:267)