Proservo NMS5
122
Hauser
Matrix group
Function group
Item
Access
code
Short description
Default value
Set
Select
Display
Possible settings,
selection, or display
Index No,
GVH
CALIBRATION
CALIBRATION
51
154
51
153
50
Calibrate NMS5 Proservo level display equal to manual
dip level. With Operation = Level and NMS in balance status use
+/- and E keys to adjust / set the data.
16000.0 mm
Set
0 - 99999.9 mm
150
0.000 mm/m
Set
0 - 59.999 mm/m
Set
SET LEVEL
TANK CORRECT LEV.
51
Start level for tank roof compensation by level. This compensation
is used in case of tank roof distortion due to hydrostatic pressure
on tank wall.
0.0 mm
Set
0 - 99999.9 mm
152
TANK CORRE. COEF.
,INEARCOEFlCIENTFORTANKROOFCOMPENSATIONBYLEVEL
SAFE DENSITY
3ELECTTHEDESIREDRESULTANTCONDITIONWHENDENSITYPROlLE
measurement fails due to displacer reaching the low-limit for
DENSITYPROlLEOPERATIONSETIN'6(
Selecting "ON" will result in STOP operation. Selecting "IGNOR"
will result in"LEVEL" operation, displacer will return to liquid
level.
Selecting "OFF" will leave the displacer at the position where
DENSITYPROlLEMEASUREMENTFAILED
OFF
OFF
ON
IGNOR
DEN. OPE. LEVEL
51
Set the lower limit for displacer movement during
DENSITYPROlLEOPERATION
300 mm
Set
0 - 99999.9 mm
155
SERVICE MODE
PROSAFETY
SAFETY LEVEL
530
530
530
Deactivate Prosafety function during maintenance;
level value not valid.
Proactive safety function outputs maximum level value during
SPECIlEDERRORCONDITIONS
Adjust maximum level output value, depending on receiver
SPECIlCATION
OFF
ON
99999.0 /
65000.0
Set
Set
Set
ON / OFF
ON / OFF
0...99999.0
157
158
159