Proservo NMS5
62
Hauser
7.5
Remote Communications
7.5.1
Digital Output
The desired loop address for most digital protocols can be set at G2V8H5 (Address). The allowable range for
setting varies depending on the protocol installed in NMS5. The range has 0-9, 00-FF (FF is fixed for MIC pro-
tocol), or 1-247 for Modbus.
•
WM550 and Mark Space protocols addresses must be set by switches on the communications module inside
NMS5.
•
MODBUS: Termination resistors should be set on BODBUS modules (refer to Appendix "13.1 RS-485
MODBUS (COMM-5) Terminator").
•
Enraf BPM: Address range is 00-99. A-F is not available.
7.5.2
Whessoe Matic 550 (WM550) Communication Board Setting
Jumper Setting
Jumper settings for WM550 communication board
To loaded software into processor [IC1] J3 has to be open.
If software testing is required; J4 has to be open.
If software reset is required; J6 has to be short.
Polling Address Setting
Caution!
Polling addresses are set by mechanically at SW1 on WM550 communication board (not by
acccessing NMS programming matrix). Check all polling addresses before setting.
The following table shows about address setting.
Note!
For current loop setting, refer a operating manual for Whessoe 1098 or RTU 8130 operating manual.
Jumper
Function
Default Condition
J3 (Mode)
Use EPROM [IC4]->short
Short
J4 (Test)
Software testing
Short
J6 (Reset)
Reset
Open
J7 (Watch dog)
Watch dog setting
Short
Switch Position
Value
1
1
2
2
3
4
4
8
5
16
6
COMPATIBILITY
MODE
ON
1
2
3
4
5
6
Polling address = 1
ON
1
2
3
4
5
6
Polling address = 5
ON
1
2
3
4
5
6
Polling address = 9
ON
1
2
3
4
5
6
Polling address = 3
ON
1
2
3
4
5
6
Polling address = 7
Setting Example