14.3.2
PTFE Displacer Installation
Installation Procedure
1.
Remove the screw using a flathead screwdriver.
2.
Mount the displacer on the teflon-ring.
3.
PTFE Wire
: Install the ground wire of the displacer from the wire insertion slot until the ground wire
touches to the wall of the screw hole.
4.
SUS Wire
: Install the ground wire of the displacer from the wire insertion slot until the ground wire
touches to the wall of the screw hole. Then install the ground wire 10mm farther.
5.
Tighten the screw.
•
Hold the ground wire with finger tip so that the wire does not come out from the slot.
6.
Lift the displacer using the flathead screwdriver and confirm that the ground wire does not come out from
the slot.
This completes the installation procedure.
Figure. 112: PTFE Displacer
㻝㻜㼙㼙
Step 1
Step 2
Step 3: PTFE Wire
Step 4: SUS Wire
Step 5
Step 6
Finger Tip
4EmONRING
)NSERTION(OLEFOR7IRE
PTFE Screw (M5)
$ISPLACER
3CREW(OLE
'ROUND7IREFOR$ISPLACER
14 Appendix