Deflection plate with calibration ring
A Deflection Plate is mounted at the lower end of the still-pipe and is integrated with a ring
that is used for calibrating the gauge during the installation phase when the tank is empty.
Installation instructions are enclosed with the Verification Pin and Deflection Plate.
Figure 3-12: Still-pipe with Deflection Plate and Verification Pin
$
%
'
(
&
A. Still-pipe
B. Support
C. Minimum 150 mm (6 in.)
D. Calibration ring
E. Deflection plate
The Deflection Plate can be attached to the still-pipe by using one of three methods:
•
Welding
•
M4 screw and nut
•
Riveting
For pipe dimensions 4 inch SCH 40 and DN 100, an extra ring is needed for the Deflection
Plate as illustrated in
.
and the Rosemount Tank Gauging
for
further information on how to configure the Rosemount 5900S for LPG/LNG
measurements.
Reference Manual
Installation
00809-0100-5900
September 2019
Rosemount 5900S Radar Level Gauge
43
Содержание Rosemount 5900S Series
Страница 1: ...Reference Manual 00809 0100 5900 Rev EA September 2019 Rosemount 5900S Radar Level Gauge ...
Страница 6: ...Contents Reference Manual September 2019 00809 0100 5900 vi Reference Manual ...
Страница 12: ...Introduction Reference Manual September 2019 00809 0100 5900 12 Reference Manual ...
Страница 182: ...Configuration Reference Manual September 2019 00809 0100 5900 182 Reference Manual ...
Страница 186: ...Operation Reference Manual September 2019 00809 0100 5900 186 Reference Manual ...
Страница 222: ...Service and troubleshooting Reference Manual September 2019 00809 0100 5900 222 Reference Manual ...
Страница 266: ...Product Certifications Reference Manual September 2019 00809 0100 5900 266 Reference Manual ...