Figure 3-30: Rosemount 5900S Wiring Diagram
A. Rosemount TankMaster PC
B. Rosemount 2410 Tank Hub
C. Field communicator
D. Tankbus
E. Power supply
F. Shield
G. Rosemount 2240S Multi-input Temperature Transmitter with built-in terminator
H. Rosemount 5900S Radar Level Gauge
See also
for information on terminal block connections.
The Rosemount 5900S 2-in-1 version
The 2-in-1 version of the Rosemount 5900S has two separate level gauges in the same
housing. One of the tankbuses can be terminated in the Rosemount 5900S terminal
compartment.
The 2-in-1 version can be connected to two separate tankbuses as illustrated in
, or to a single tankbus as illustrated in
Terminal X1 is an intrinsically safe tankbus input for level gauge 1, and terminal X4
connects to the second level gauge.
illustrates a wiring diagram with a 2-in-1 version of the Rosemount 5900S
Radar Level Gauge which is “daisy-chained” to a Rosemount 2240S Multi-input
Reference Manual
Installation
00809-0100-5900
September 2019
Rosemount 5900S Radar Level Gauge
91
Содержание Rosemount 5900S Series
Страница 1: ...Reference Manual 00809 0100 5900 Rev EA September 2019 Rosemount 5900S Radar Level Gauge ...
Страница 6: ...Contents Reference Manual September 2019 00809 0100 5900 vi Reference Manual ...
Страница 12: ...Introduction Reference Manual September 2019 00809 0100 5900 12 Reference Manual ...
Страница 182: ...Configuration Reference Manual September 2019 00809 0100 5900 182 Reference Manual ...
Страница 186: ...Operation Reference Manual September 2019 00809 0100 5900 186 Reference Manual ...
Страница 222: ...Service and troubleshooting Reference Manual September 2019 00809 0100 5900 222 Reference Manual ...
Страница 266: ...Product Certifications Reference Manual September 2019 00809 0100 5900 266 Reference Manual ...