199
z
Troubleshooting Guide
chap.6
(7) "E008" is displayed
(8) "E009" is displayed
Cause/Detective section Procedures
Result
Countermeasure
Items to be checked
I/F PCB Unit
1
Is the cause cleared by replacing the
I/F set PCB Unit ?
YES
Finish.
Online code
2
Is the cause cleared by replacing the
online code ?
YES
Finish.
IPC I/F PCB Unit
3
Is the cause cleared by replacing the
IPC I/F PCB Unit ?
YES
Finish.
P-memory PCB Unit
4
Is the cause cleared by replacing the P-
memory PCB Unit ?
YES
Finish.
Main PCB Unit
NO
Check the bundled wire between the I/F
PCB unit CN4 and the P-memory PCB
CN3. If OK, replace the main PCB unit.
In platemaking, measure the voltage
between the regulated power supply, +S
(+24) and -S(GND) with the tester. Is it
+24V?
Cause/Detective section Procedures
Result
Countermeasure
Items to be checked
Thermal head
1
Disconnect all the thermal head
connectors, and cheked using HELP03*
( Thermal head power source).
Is the voltage 16-18V approx.?
Is the voltage 24V approx.?
DP-430/330/330L :
DP-460/440/340 :
YES
Chech the bundled wire and connector.
If OK, replace the thermal head.
DC-DC PCB Unit
2
YES
Chech the bundled wire and connector.
If OK, replace the DC-DC PCB Unit.
Regulated power supply
NO
Replace the regulated power supply.
HELP mode H-03
\
see p.228
*
Содержание Duprinter DP-330
Страница 9: ......
Страница 11: ......
Страница 18: ...c Dimensions chap 1 17 MEMO...
Страница 24: ...4 8 2A 2B 2C 44000A1e b Part Names and Their Functions chap 1 23...
Страница 152: ...151 MEMO...
Страница 193: ...192 MEMO...
Страница 328: ...327 x Overall Wiring Layout chap 8 14 2 Overall Wiring Layout 2 Overall Wiring Layout 2 Drive PCB 1 2 O...
Страница 329: ...328 x Overall Wiring Layout chap 8 15 Overall Wiring Layout 2 Drive PCB 2 2...