Changing settings
●
Press the softkey »
parameter
«.
●
Move the cursor frame to »
NiBP
« with the rotary
control and press to confirm.
The menu for setting the parameter is displayed.
auto
on / off
Activates automatic measurements at
the specified time intervals.
punction
Start / Stop
Starts or stops venous congestion.
Inflation ends automatically after
2 minutes.
measurement
Start / Stop / Turbo
»Start
« Triggers manual measure-
ment outside the automatic
time interval.
»Stop
« Stops
a
measurement.
Or press the
‚
key on
the parameter box.
»Turbo
« Five simplified measure-
ments in five minutes.
This mode can also be
stopped with »
Stop
«.
time interval
2 / 3 / 5 / 10 / 15
Selects the time interval for automatic
measurement in minutes. The starting
time for the next automatic measure-
ment is not affected by a measure-
ment triggered manually between two
automatic measurements.
active alarms
sys / dia
Determines whether the systolic or
diastolic pressure is to be monitored.
punction pressure numerical
(separate for adults and neonates)
Sets the punction inflation pressure
of the sphygmomanometer cuff.
The cuff is inflated to the preset
starting pressure for the first
measurement; after reading off the
systolic pressure, the cuff is inflated
to 20 mmHg above the last
measured systolic value for the next
measurement. If the inflation
pressure is too low for correct
measurement of the systolic
pressure, air is automatically released
from the cuff and the measurement is
Parameter box
Non-invasive blood pressure (NiBP)
92
11:59
00:00
IPPV alarm limits
standard screen 1- adults
Warning:
Caution:
Advisory:
2. ECG
II
1mV
iBP1
160
0
0
CO
2
40
30
PAW
20
0
33
6.0
freq 10 V
T
0.60
36.8 37.2
pulse def. 4 ST + 0.05
65
122/ 89
pulse 65 (100)
32 3
plat 26 mean 21
pulse 65
99
O
2
N
2
O ISO
Fi
29 70 0.8
Fet
26 68 0.6
ª
auto set
pat. alarm.
timer
start
config.
alarm
info
screen
config.
limits
auto set
vent. al.
para-
meter
Select a menu position. Please confirm !
Change the settings. Please confirm again !
NiBP
auto on off
punction Start Stop
measure Start Stop Turbo
units mmHg kPa
interlock:
NiBP-SpO
2
on off
NiBP-iBP on off
punction pressure 40 mmHg
initial pressure 180 mmHg
active alarms sys dia
time interval 5
06-12-98
etCO
2
mmHg
MV L/min
T
1
T
2
°
C
HR/Pulse (ECG)
1/min
iBP1 ART mmHg
Peak mbar PEEP
SpO
2
%
Fi CO
2
0
NiBP
auto on off
punction Start Stop
measure Start Stop Turbo
units mmHg kPa
interlock:
NiBP-SpO
2
on off
NiBP-iBP on off
punction pressure 40 mmHg
initial pressure 180 mmHg
active alarms sys dia
time interval 5
15429278
15529278