Configuring screens
Three standard screens can be configured and stored
independently of one another. The colour configuration of
the screen can be defined. The following menu options
are available:
–
Standard screen 1
–
Standard screen 2
–
Standard screen 3
–
Colour
–
Curve speed
–
General settings
The screens are made up of »
Graphs
« and »
Modules
«
which can be selected via the menu with the aid of the
rotary control.
Configuring standard screen 1 (or 2 or 3)
Example:
The screen structure is shown schematically on the left-
hand side of the screen. Alongside it, there is a table of
graphical and numerical modules for selection.
Modules which have already been selected are shown
against an orange background.
●
Turn the rotary control to move the rectangular cursor
bar (yellow) to the desired module or graph in the
table.
●
Press the rotary control to confirm.
The selected item in the table is highlighted against a
white background and is displayed in the schematic
illustration on the left, framed by the rectangular
yellow cursor bar.
●
It can be moved in the schematic with the aid of the
rotary control.
●
When the rotary control is pressed to confirm, the
module is then locked in that position on the screen.
●
The module is deleted by pressing »
Delete
«.
The standard screen selected by this method is activated
●
every time the device is switched on
●
on quitting the described standard screen
configuration.
●
on calling up »
Standard
« in the operating
configuration.
Observe national regulations on the minimum
measurement parameters to be monitored!
53
System screen functions
Configuring the system screen in »Standby«
Screen configuration menu. Please confirm !
Standby / Configuration
11:59
00:00
alarms inactive !
Settings
mode
adult neon.
alarm limits
parameter
screen
acoustic
list entry
transport
RS 232 (Medibus)
record (printer)
basic config.
standard - screen 1
standard - screen 2
standard - screen 3
colour
curve speed
general settings
06-12-98
Settings
11:59
00:00
06-12-98
Select a graph or a module by turning the rotary knob. Please confirm !
Standby / Configuration
alarms inactive !
mode adult neon.
alarm limits
parameter
screen
acoustic
list entry
transport
RS 232 (Medibus)
record (printer)
basic config.
Please observe your national
monitoring requirements.
standard - screen 1
Patient
Graph
Module
Graph
Module
Ventilation
1. ECG
2. ECG
3. ECG
iBP1
iBP2
iBP1+iBP2
Pleth
CO
2
CO
2
short
CO
2
double
PAW
PAW short
PAW double
flow
flow short
AGas
O
2
N
2
O
CO
2
combi-vent
press. 1
press. 2
MV
volumeter
Gases
O
2
Econometer
HR
pEEG
temp
iBP1
iBP2
NiBP
SpO
2
combi-haem
combi-haem
combi-vent
delete
1. ECG
iBP1
HR
PAW
press. 1
SpO
2
MV
CO
2
O
2
CO
2
08929278
09029278