Chapter 4 Parameters
4-115
06.15
Detected Current Bandwidth
Unit: %
Settings
2 ~100.0 %
Factory Setting: 2
06.16
Detected DC Brake Time of Output Phase Loss
Unit: second
Settings
0.0 ~120.0 seconds
Factory Setting: 0.1
Set Pr.06.13~06.16 can detect the driver output is disconnected or not.
Open this function may cause misjudgment due to load or starting voltage is too small, here
we can extend the detection time appropriately (Pr.06.14&Pr.06.16) or set Pr.06.15 value
smaller.