Chapter 4 Parameters
4-22
Group 7 Motor Parameters
Parameter Explanation
Settings
Factory
Setting
Customer
07.00
Motor Rated Current
(Motor 0)
30 %FLA to 120% FLA
FLA
07.01
Motor No-Load
Current (Motor 0)
0%FLA to 99% FLA
0.4*FLA
07.02
Torque
Compensation
(Motor 0)
0.0 to 10.0
0.0
07.03 Slip
Compensation
(Used without PG)
(Motor 0)
0.00 to 10.00
0.00
07.04
Motor Parameters
Auto Tuning
0: Disable
1: Auto tuning R1
2: Auto tuning R1 + no-load test
0
07.05
Motor Line-to-line
Resistance R1
(Motor 0)
0~65535 m
Ω
0
07.06
Motor Rated Slip
(Motor 0)
0.00 to 20.00 Hz
3.00
07.07
Slip Compensation
Limit
0 to 250%
200
07.08
Torque
Compensation Time
Constant
0.01 ~10.00 Sec
0.30
07.09
Slip Compensation
Time Constant
0.05 ~10.00 sec
0.20
07.10
Accumulative Motor
Operation Time
(Min.)
0 to 1439 Min.
##
07.11
Accumulative Motor
Operation Time
(Day)
0 to 65535 Day
##
07.12
Motor PTC
Overheat Protection
0: Disable
1: Enable
0
07.13
Input Debouncing
Time of the PTC
Protection
0~9999(*2ms) 100
Содержание VFD-E Series
Страница 271: ...B 6 B 1 4 DIN Rail Installation...
Страница 304: ...B 39 Driver Installation After connecting IFD6500 to PC please install driver by following steps...
Страница 305: ...B 40 LED Display 1 Steady Green LED ON power is ON 2 Blinking orange LED data is transmitting...
Страница 306: ...B 41 B 9 DIN Rail B 9 1 MKE DRA Unit mm inch SCREW M4 2X 20 22 Kgf cm...
Страница 335: ...D 8 In ladder diagram mode you can perform program editing using the buttons on the function icon row Basic Operation...