E-13
Index
Sub
Definition
Factory
Setting
R/W Size Unit
NOTE
1 COB-ID used by PDO
0x80000300
+Node-ID
RW U32
2 Transmission
Type
5
RW U8
00:Acyclic &
Synchronous
01~240:Cyclic &
Synchronous
255: Asynchronous
0x1600
0 Number
2
RW U8
1 1.Mapped
Object
0x60400010
RW U32
2 2.Mapped
Object
0x60420020
RW U32
3 3.Mapped
Object
0
RW U32
4 4.Mapped
Object
0
RW U32
0x1601
0 Number
0
RW U8
1 1.Mapped
Object
0
RW U32
2 2.Mapped
Object
0
RW U32
3 3.Mapped
Object
0
RW U32
4 4.Mapped
Object
0
RW U32
0x1800
0 Number
5 RO U8
1 COB-ID used by PDO
0x00000180
+Node-ID
RW U32
2 Transmission
Type
5
RW U8
00:Acyclic &
Synchrouous
01~240:Cyclic &
Synchrouous
253: Remote
function
255: Asynchronous
3 Inhibit
time
0
RW U16 100us
It is set to be
multiple of 10.
4 Reserved
3
RW U8
Reserved
5 Event
timer
0
RW U16
1ms
0x1801
0 Number
5 RO U8
1 COB-ID used by PDO
0x80000280
+Node-ID
RW U32
2 Transmission
Type
5
RW U8
00:Acyclic &
Synchrouous
01~240:Cyclic &
Synchrouous
253: Remote
function
255: Asynchronous
3 Inhibit
time
0
RW U16 100us
It is set to be
multiple of 10.
4 Reserved
3
RW U8
5 Event
timer
0
RW U16
1ms
0x1A00
0 Number
2
RW U8
1 1.Mapped
Object
0x60410010
RW U32
2 2.Mapped
Object
0x60430010
RW U32
3 3.Mapped
Object
0
RW U32
4 4.Mapped
Object
0
RW U32
Содержание VFD-E Series
Страница 271: ...B 6 B 1 4 DIN Rail Installation...
Страница 304: ...B 39 Driver Installation After connecting IFD6500 to PC please install driver by following steps...
Страница 305: ...B 40 LED Display 1 Steady Green LED ON power is ON 2 Blinking orange LED data is transmitting...
Страница 306: ...B 41 B 9 DIN Rail B 9 1 MKE DRA Unit mm inch SCREW M4 2X 20 22 Kgf cm...
Страница 335: ...D 8 In ladder diagram mode you can perform program editing using the buttons on the function icon row Basic Operation...