D-34
D.4.8 Special Auxiliary Relays
Special
M
Function
Read(R)/
Write(W)
M1000
Normally open contact (a contact). This contact is On when running and it is
On when the status is set to RUN.
R
M1001
Normally closed contact (b contact). This contact is Off in running and it is Off
when the status is set to RUN.
R
M1002
On only for 1 scan after RUN. Initial pulse is contact a. It will get positive
pulse in the RUN moment. Pulse width=scan period.
R
M1003
Off only for 1 scan after RUN. Initial pulse is contact a. It will get negative
pulse in the RUN moment. Pulse width=scan period.
R
M1004 --
--
M1005 Fault indication of the AC motor drives
R
M1006 ON = STOP, OFF = RUN
R
M1007 The operation direction of AC motor drives (FWD: 0, REV: 1)
R
M1008 --
--
M1009 --
--
M1010 Switch AFM Setting Range (0: 0~65536 1: 0~10000)
R/W
M1011 10ms clock pulse, 5ms On/5ms Off
R
M1012 100ms clock pulse, 50ms On / 50ms Off
R
M1013 1s clock pulse, 0.5s On / 0.5s Off
R
M1014 1min clock pulse, 30s On / 30s Off
R
M1015 Frequency
attained
R
M1016 Parameter
read/write
fault
R
M1017 Succeed to write parameter
R
M1018 Enable high-speed counter function (When M1028=On)
R
M1019 --
--
M1020 Zero
flag
R
M1021 Borrow
flag
R
M1022 Carry
flag
R
M1023 Divisor
is
0
R
M1024 --
--
Содержание VFD-E Series
Страница 271: ...B 6 B 1 4 DIN Rail Installation...
Страница 304: ...B 39 Driver Installation After connecting IFD6500 to PC please install driver by following steps...
Страница 305: ...B 40 LED Display 1 Steady Green LED ON power is ON 2 Blinking orange LED data is transmitting...
Страница 306: ...B 41 B 9 DIN Rail B 9 1 MKE DRA Unit mm inch SCREW M4 2X 20 22 Kgf cm...
Страница 335: ...D 8 In ladder diagram mode you can perform program editing using the buttons on the function icon row Basic Operation...