Chapter 4 Parameters
4-180
Group 4 Input Function Parameters
Parameter Explanation
Settings
Factory
Setting
Customer
04.05 Multi-function
Input
Terminal (MI3)
0: No function
1
1: Multi-Step speed command 1
2: Multi-Step speed command 2
04.06 Multi-function
Input
Terminal (MI4)
3: Multi-Step speed command 3
2
4: Multi-Step speed command 4
5: External reset
04.07 Multi-function
Input
Terminal (MI5)
6: Accel/Decel inhibit
3
7: Accel/Decel time selection command
8: Jog Operation
04.08 Multi-function
Input
Terminal (MI6)
9: External base block
23
10: Up: Increment master frequency
11: Down: Decrement master frequency
12: Counter Trigger Signal
13: Counter reset
14: E.F. External Fault Input
15: PID function disabled
16: Output shutoff stop
17: Parameter lock enable
18: Operation command selection (external
terminals)
19: Operation command selection(keypad)
20: Operation command selection
(communication)
21: FWD/REV command
22: Source of second frequency command
23: Quick Stop (Only for VFD*E*C models)
24: Download/execute/monitor PLC Program
(PLC2) (NOT for VFD*E*C models)
25: Simple position function
26: OOB (Out of Balance Detection)
Содержание VFD-E Series
Страница 271: ...B 6 B 1 4 DIN Rail Installation...
Страница 304: ...B 39 Driver Installation After connecting IFD6500 to PC please install driver by following steps...
Страница 305: ...B 40 LED Display 1 Steady Green LED ON power is ON 2 Blinking orange LED data is transmitting...
Страница 306: ...B 41 B 9 DIN Rail B 9 1 MKE DRA Unit mm inch SCREW M4 2X 20 22 Kgf cm...
Страница 335: ...D 8 In ladder diagram mode you can perform program editing using the buttons on the function icon row Basic Operation...