Chapter 5 Troubleshooting
|
5-1
Chapter 5 Troubleshooting
5.1 Over Current (OC)
ocA
ocd
OC
Over-current
during acceleration
Over-current
during deceleration
Over current
Check if there is any
between the U, V, W and motor
short circuits and
grounding
Yes
No
No
No
No
No
No
Yes
Yes
Yes
Remove short circuit
or ground fault
Reduce the load or
increase the power
of AC motor drive
No
No
Reduce torque
compensation
Reduce torque
compensation
Suitable torque
compensation
No
No
No
No
No
Yes
Yes
Yes
Yes
Yes
Maybe AC motor drive
has malfunction or error
due to noise. Please
contact DELTA.
Can acceleration
time be made longer?
Can deceleration
time be made longer?
Reduce load or increase
the power of AC motor
drive
Check braking
method. Please
contact DELTA
Reduce load or increase
the power of AC motor
drive
Has load changed
suddenly?
Check if
acceleration time
is too short by
load inertia.
Check if
deceleration time
is too short by
load inertia.
Increase accel/decel
time
Check if load is too large
Содержание VFD-E Series
Страница 271: ...B 6 B 1 4 DIN Rail Installation...
Страница 304: ...B 39 Driver Installation After connecting IFD6500 to PC please install driver by following steps...
Страница 305: ...B 40 LED Display 1 Steady Green LED ON power is ON 2 Blinking orange LED data is transmitting...
Страница 306: ...B 41 B 9 DIN Rail B 9 1 MKE DRA Unit mm inch SCREW M4 2X 20 22 Kgf cm...
Страница 335: ...D 8 In ladder diagram mode you can perform program editing using the buttons on the function icon row Basic Operation...