Chapter 4 Parameters
4-72
02.17
Display the Operation Command Source
Settings
Read Only
Factory display: 4
You can read the operation source by this parameter.
Display Value
Bit
Function
1
Bit0=1 Operation Command Source by Digital Keypad
2
Bit1=1 Operation Command Source by RS485 communication
4
Bit2=1 Operation Command Source by External Terminal
8
Bit3=1 Operation Command Source by Multi-input function
16 Bit4=1
Operation Command Source by PLC Operation Command
(NOT for VFD*E*C models)
32
Bit5=1 Operation Command Source by CANopen Communication Interface
When it displays 8, it means that the operation command source is from multi-input function.
Thus, when Pr.04.05~04.08 are set to 8(Jog Operation), 18(Operation command selection
(external terminals)), 19(Operation command selection(keypad)), 20(Operation command
selection (communication)) and 21(FWD/REV command), it will display 8 in Pr.02.17.
Pr.04.05(Multi-function Input Terminal (MI3)), Pr.04.06(Multi-function Input Terminal (MI4)),
Pr.04.07(Multi-function Input Terminal (MI5)), Pr.04.08(Multi-function Input Terminal (MI6))