Chapter 4 Parameters
4-83
E-5
AC/DC
Motor
Load
magnetic plate
Example:
When using Pr.03.11 and Pr.03.12 are used in life equipment as above figure. The timing
figure is shown as follows. The DC brake is used before start-up and after stop. It can have
high output torque at the beginning of start-up. The Brake Release Frequency (Pr.03.11) can
be set by the requirement. The Brake Engage Frequency (Pr.03.12) can be set by requirement
to be used when stopping near 0Hz to prevent vibration of counterforce for smooth operation.
RUN
STOP
ON
OFF
RUN/STOP
Output frequency (H)
setting
frequency
03.11
Brake release frequency
03.12
Brake engage frequency
DC brake
DC brake
08.01
DC brake time
during start-up
08.02
DC brake time
during stopping
Brake control
(MO1=21)
Pr.03.00~03.01 Multi-function Output Terminal:24
『
Function of Output Frequency
Control Multi-output terminal ON/OFF
』
: When output frequency is greater than
Pr.03.11(Brake Release Frequency),
this multi-function output terminal is conducted
;
When output frequency is less than Pr.03.11 (Brake Release Frequency),
this multi-
function output terminal is open circuit.
Please note that when you select this function,
Pr.03.11 MUST be greater than Pr.03.12, otherwise the multi-function output terminal is
always in open circuit condition.
Related
parameters
:
03.00 Multi-function Output (Relay)
、
03.01 Multi-function Output
Terminal (MO1)
Содержание VFD-E Series
Страница 271: ...B 6 B 1 4 DIN Rail Installation...
Страница 304: ...B 39 Driver Installation After connecting IFD6500 to PC please install driver by following steps...
Страница 305: ...B 40 LED Display 1 Steady Green LED ON power is ON 2 Blinking orange LED data is transmitting...
Страница 306: ...B 41 B 9 DIN Rail B 9 1 MKE DRA Unit mm inch SCREW M4 2X 20 22 Kgf cm...
Страница 335: ...D 8 In ladder diagram mode you can perform program editing using the buttons on the function icon row Basic Operation...