Wiring Diagrams for Reference
SiUS34-801A_b
504
Appendix
Heat Recovery 230V
REYQ168, 192, 216, 240PTJU
2 WIRES CABLE
6) Unit shall be grounded in compliance with the applicable local
and national codes.
7) Wiring shown are general points-of-connection guides only and
are not intended for or to include all details for a specific
installation.
8) Be sure to install the switch and the fuse to the power line of
each equipment.
9) Install the main switch that can interrupt all the power souces in
an integrated manner because this system consists of the
equipment utilizing the multiple power sources.
10) The capacity of UNIT1 must be larger than UNIT2 when the
power source is connected in series between the units.
11) If there exists the possibility of reversed phase, lose phase,
momentary blackout or the power goes on and off while the
product is operating, attach a reversed phase protection circuit
locally.
Running the product in reversed phase may break the
compressor and other parts.
Notes 1) All wiring, components and materials to be procured on the site must
comply with the applicable local and national codes.
2) Use copper conductors only.
3) As for details, see wiring diagram.
4) Install ground fault circuit interrupter for safety.
5) All field wiring and components must be provided by licensed electrician.
[UNIT 1]
[UNIT 2]
POWER SUPPLY
POWER SUPPLY
L1
L2
L1
L2
L3
L3
L1
L2
L3
COOLING ONLY UNIT
MAIN
SWITCH
MAIN
SWITCH
FUSE
SWITCH
(TRANSMISSION LINE)
2 WIRES CABLE
(TRANSMISSION LINE)
2 WIRES CABLE
(TRANSMISSION LINE)
2 WIRES CABLE
(TRANSMISSION LINE)
2 WIRES CABLE
(TRANSMISSION LINE)
2 WIRES CABLE
(TRANSMISSION LINE)
2 WIRES CABLE
(TRANSMISSION LINE)
2 WIRES CABLE
(TRANSMISSION LINE)
2 WIRES CABLE
(TRANSMISSION LINE)
2 WIRES CABLE
< When the power source is supplied to each outdoor unit individually. >
L1
L2
SWITCH
FUSE
OUTDOOR UNITS
L1
L2
L1
L2
L1
L2
SWITCH
FUSE
L1
L2
SWITCH
FUSE
SWITCH
FUSE
L1
L2
L1
L2
SWITCH
FUSE
L1
L2
SWITCH
FUSE
L1
L2
SWITCH
FUSE
SWITCH
FUSE
SWITCH
FUSE
2 WIRES CABLE
(POWER LINE)
2 WIRES CABLE
(POWER LINE)
2 WIRES CABLE
(POWER LINE)
2 WIRES CABLE
(POWER LINE)
2 WIRES CABLE
(POWER LINE)
(POWER LINE)
2 WIRES CABLE
(POWER LINE)
2 WIRES CABLE
(POWER LINE)
INDOOR UNITS
BS UNITS
3D059671
Содержание RXYQ96PYDN
Страница 15: ...SiUS34 801A_b xiv...
Страница 23: ...Model Selection SiUS34 801A_b 8 General Information...
Страница 133: ...Field Settings SiUS34 801A_b 118 VRVIII R 410A Heat Pump 60Hz...
Страница 254: ...SiUS34 801A_b Test Operation VRVIII R 410A Heat Recovery 60Hz 239 R 410A Label R 410A Label...
Страница 329: ...Field Setting SiUS34 801A_b 314 Indoor Unit...
Страница 340: ...SiUS34 801A_b Troubleshooting by Remote Controller Troubleshooting 325...
Страница 489: ...Piping Diagrams SiUS34 801A_b 474 Appendix 1 Piping Diagrams 1 1 Outdoor Unit Heat Pump 460V RXYQ72 96 120PYDN 3D058636A...
Страница 490: ...SiUS34 801A_b Piping Diagrams Appendix 475 Heat Pump 230V RXYQ72 96 120PTJU 3D058636A...
Страница 491: ...Piping Diagrams SiUS34 801A_b 476 Appendix Heat Pump 230V RXYQ144PTJU 3D058640...
Страница 492: ...SiUS34 801A_b Piping Diagrams Appendix 477 Heat Recovery 460V REYQ72 96 120PYDN 3D058639A...
Страница 493: ...Piping Diagrams SiUS34 801A_b 478 Appendix Heat Recovery 460V REMQ72PYDN 3D058637A...
Страница 494: ...SiUS34 801A_b Piping Diagrams Appendix 479 Heat Recovery 460V REMQ96 120PYDN 3D058638A...
Страница 495: ...Piping Diagrams SiUS34 801A_b 480 Appendix Heat Recovery 230V REYQ72 96 120PTJU 3D058639A...
Страница 496: ...SiUS34 801A_b Piping Diagrams Appendix 481 Heat Recovery 230V REYQ144PTJU 3D058640...
Страница 497: ...Piping Diagrams SiUS34 801A_b 482 Appendix Heat Recovery 230V REMQ72PTJU 3D058637A...
Страница 498: ...SiUS34 801A_b Piping Diagrams Appendix 483 Heat Recovery 230V REMQ96 120PTJU 3D058638A...
Страница 501: ...Piping Diagrams SiUS34 801A_b 486 Appendix 1 3 BS Unit 4D057985A...
Страница 537: ...Piping Installation Point SiUS34 801A_b 522 Appendix...
Страница 543: ...Pressure Sensor SiUS34 801A_b 528 Appendix...
Страница 559: ...Precautions for New Refrigerant R 410A SiUS34 801A_b 544 Precautions for New Refrigerant R 410A...
Страница 563: ...SiUS34 801A_b iv Index...