Option List
SiBE37-701_B
441
Appendix
Building Management System
Notes:
★
1. BACnet
®
is a registered trademark of American Society of Heating, Refrigerating and Air-
Conditioning Engineers (ASHRAE).
★
2. LonWorks
®
‚ is a registered trade mark of Echelon Corporation.
★
3. Installation box for
adaptor must be procured on site.
No.
Part name
Model No.
Function
1
intelligent Touch
Controller
Basic
Hardware
intelligent Touch
Controller
DCS601C51
• Air-Conditioning management system that can be controlled by a
compact all-in-one unit.
1-1
Option
Hardware
DIII-NET plus adaptor
DCS601A52
• Additional 64 groups (10 outdoor units) is possible.
1-2
Software
P. P. D.
DCS002C51
• P. P. D.: Power Proportional Distribution function
1-3
Web
DCS004A51
• Monitors and controls the air conditioning system using the Internet
and a Web browser application on a PC.
1-4
Electrical box with earth terminal (4 blocks)
KJB411A
• Wall embedded switch box.
2
intelligent
Manager III
Basic
Hardware
Number of
units to be
connected
128 units
DAM602B52
• Air conditioner management system that can be controlled by
personal computers.
256 units
DAM602B51
512 units
DAM602B51×2
768 units
DAM602B51×3
1024 units
DAM602B51×4
2-1
Option
Software
P.P.D.
DAM002A51
• Power Proportional Distribution function
2-2
Web
DAM004A51
• Monitors and controls the air conditioning system using the Internet
and a Web browser application on a PC.
2-3
Eco
DAM003A51
• ECO (Energy saving functions.)
2-4
Optional DIII Ai unit
DAM101A51
• External temperature sensor for intelligent Manager III.
2-5
Di unit
DEC101B51
• Input contacts: 16 points
2-6
Dio unit
DEC102B51
• Input contacts: 8 points; output contacts: 4 points
3
C
o
m
m
u
n
ica
tio
n
lin
e
*1 Interface for use in BACnet
®
DMS502B51
• Interface unit to allow communications between VRV and BMS.
Operation and monitoring of air-conditioning systems through
BACnet
®
communication.
3-1
Optional DIII board
DAM411B51
• Expansion kit, installed on DMS502B51, to provide 2 more DIII-NET
communication ports. Not usable independently.
3-2
Optional Di board
DAM412B51
• Expansion kit, installed on DMS502B51, to provide 16 more
wattmeter pulse input points. Not usable independently.
4
*2 Interface for use in LonWorks
®
DMS504B51
• Interface unit to allow communications between VRV and BMS.
Operation and monitoring of air-conditioning systems through
LonWorks
®
communication.
5
C
o
ntac
t/an
a
lo
g
si
gn
al
Parallel interface
Basic unit
DPF201A51
• Enables ON/OFF command, operation and display of malfunction;
can be used in combination with up to 4 units.
6
Temperature
measurement units
DPF201A52
• Enables temperature measurement output for 4 groups; 0-5VDC.
7
Temperature
setting units
DPF201A53
• Enables temperature setting input for 16 groups; 0-5VDC.
8
Unification adaptor for
computerized control
★
DCS302A52
• Interface between the central monitoring board and central control
units.
[
Содержание REYQ8-48PY1B
Страница 1: ...Service Manual REYQ8 48PY1B R 410A Heat Recovery 50Hz SiBE37 701_B ...
Страница 456: ...Piping Installation Point SiBE37 701_B 445 Appendix ...
Страница 460: ...Example of connection SiBE37 701_B 449 Appendix ...
Страница 476: ...Revision History Date News No Contents 2010 9 10 M 10011 Correction of service manual ...