Compaq ES40CSLP Rackmount System Installation/User/Service Guide C–1
C
Jumpers and Switches
C.1 System Motherboard Jumpers and Sw itches
Table C-1 lists the jumpers on the system motherboard along with the name of the jumper and a
description of the settings. Figure C-1 shows the location of the system motherboard jumpers.
Table C-1 System Motherboard Jumpers
Jumper
Name
Description
J1
Debug
Used for debug. When installed, bypasses power-up checks of
processors by system power controller.
J2
Reserved
Reserved (not installed).
J3
Reserved
Reserved (not installed).
J12/13
Flash Write
1–2: Normal operation
2–3: Disable Flash write
J21
Load TIG
1–2: Load TIG from flash RAM (default)
2–3: Load TIG from serial ROM. This setting allows you to load
the TIG if the flash RAM is corrupted.
J20
Fail-safe Loader
Must be in default positions over pins 1 and 2 to enable FSL.
FIR_FUNC2
1–2 = 0, 2–3 = 1
J22
Fail-safe Loader
Jumper for enabling fail-safe loader (FSL)
FIR_FUNC1
1–2= 0, 2–3= 1
J23
Fail-safe Loader
Must be in default positions over pins 1 and 2 to enable FSL.
FIR_FUNC0
1–2= 0, 2–3 = 1
J24
RMC Flash Update
1-2: Disables RMC flash update
2-3: Enables RMC flash update (default)
J25
Setting RMC to
Defaults
1-2: Sets RMC back to defaults
2-3: Normal RMC operating mode (default)
J26
Over-Temperature
Shutdown
1-2: Causes system to shut down if over-temperature limit is
reached (default)
2-3: Permits system to continue running at over-temperature
J31
COM1 Bypass
1-2: Allows RMC to control COM1 bypass (default)
2-3: Disables COM1 bypass
No jumper installed: Forces COM1 bypass
Содержание ES40CSLP
Страница 10: ...This is some white text...
Страница 14: ...This is some white text...
Страница 46: ...This is some white text...
Страница 80: ...This is some white text...
Страница 98: ...This is some white text...
Страница 126: ...This is some white text...
Страница 188: ...This is some white text...
Страница 190: ...This is some white text...