Remote System Management
4–16 Compaq ES40CSLP Rackmount System Installation/User/Service Guide
3.
Extend the chassis for service and remove the top cover as described in Chapter 5.
4.
Remove the CPU module in the CPU1 slot as described in Chapter 5.
5.
On the system motherboard, install jumper J25 over pins 1 and 2 (see Figure 4-4).
6.
Reconnect the power cord to one of the power supplies, and then wait until the control
panel displays the message “System is down.”
7.
Disconnect the power cord from the power supply. Wait until the +5V Aux LED on the
power supply goes off before proceeding.
8.
Install jumper J25 over pins 2 and 3 to enable RMC mode.
9.
Reinstall the CPU module in the CPU1 slot and the top cover.
10.
Reconnect the power cord(s) to the power supplies.
______________________________ Note ___________________________
After the RMC has been reset to defaults, perform the setup procedures to enable
remote dial-in and call-out alerts. See Section 4.7.5.
______________________________________________________________
Figure 4-4 RMC Jumpers (Default Positions)
2 1
2
3
1
J1
J2
J3
J31
J26
J25
J24
LJ-06638