Troubleshooting and Diagnostics
Compaq ES40CSLP Rackmount System Installation/User/Service Guide 6–17
6.5.5.1 Console Event Log
If problems occur during SRM console power-up, standard error messages indicated by
asterisks (***) may be embedded in a console event log. To display the event log, use the more
el or cat el command.
_____________________________ Note____________________________
The cat el command displays the console event log in a scrolling display. To stop
the screen display from scrolling, press Ctrl/S. To resume scrolling, press Ctrl/Q.
The more el command displays the console event log one screen at a time.
______________________________________________________________
Example 6-3 Console Event Log
>>> more el
*** Error - CPU 1 failed powerup diagnostics ***
Secondary start error
EV6 BIST = 1
STR status = 1
CSC status = 1
PChip0 status = 1
PChip1 status = 1
DIMx status = 0
TIG Bus status = 1
DPR status = 0
CPU speed status = 0
CPU speed = 0
Powerup time = 00-00-00 00:00:00
CPU SROM sync = 0
*** Error - Fan 1 failed ***
*** Error - Fan 2 failed ***